"KC" certification is a national unified certification mark implemented by the Korean National Standards Committee, and lithium batteries are included in the KC certification catalog as a compulsory certification product. At present, the testing of portable secondary lithium battery packs and lithium batteries must be performed by authorized laboratories in South Korea, and cannot be transferred with the CB report of IEC 62133. After the product has passed the evaluation, a confirmation letter of declaration with a validity period of 5 years will be issued, during which no factory inspection is required.
Battery KC certification product range
1. Single cell (Cell): For portable use, the energy density per volume exceeds 400Wh/L
2. Battery (Pack): single battery is assembled in parallel
3. All portable lithium batteries with navigation function or batteries that have nothing to do with the energy density per volume are all applicable objects. (Used in harsh conditions inside the car)
4. Single batteries and batteries used in products such as portable medical devices, barcodes and credit card readers are all suitable objects
5. Carrying machine: MP3, electronic dictionary, PMP, notebook computer, digital camera, etc.
6. Non-certified objects: vehicle driving, industrial, medical or button-shaped.
standard test
Self-Regulatory Safety Confirmation, Annex 05
KC data list
1. Application form (ZRLK detection provides a fixed format)
2. Model name classification (ZRLK detection provides a fixed format)
3. Protective circuit (PCM) specification (circuit diagram, including IC circuit) (if there are Thermistor parts, please provide specification)
4. Manual in Korean or English
5. Cell and battery specifications
6. Warning transportation and other precautions and packaging method (can be placed in the product specification)
7. Korean nameplate
8. ISO9001 certificate or provide a declaration of conformity (Declaration of Conformity)
9. Factory business license (initial application for factory) battery is safety confirmation without factory inspection
10. Test sample (provide finished product with battery 30+cell 55)
11. Parts list (ZRLK detection fixed format)
12. CB certificate and IEC62133 test report of cell or battery
13. CDF list, including specifications of key components such as MOS tube and IC
14. Sample fixture
be careful:
1. In the KC application form, if the applicant is a Korean company, the factory can write the actual factory name and address. If the applicant is a non-South Korean company, the applicant and factory information must be the same person;
2. In the model division table, when selecting the ETC option, it is necessary to specify the materials used for the lithium battery in the back;
3. The parameter information in all specifications must be consistent, and the letters with the same symbol representing different meanings must be specially marked.
For the parameters and specification information of a certain series of models, the source files need to be attached;
4. There is a difference between the manual and the specification. The manual informs the end customer about the method of use, while the specification informs the product specification composition, both of which must be in Korean or English;
5. The warnings and packaging methods need to be in Korean. You can refer to the Chinese-Korean warning version provided by Barron;
6. The Korean nameplate requires the Korean representation of lithium batteries, marked with the KC logo, coded in accordance with the CB method, and left the local contact number in Korea;
7. If there is no lithium battery production scope in the ISO certificate of the applicant, a self-quality declaration is required.
Test items
1. High Temperature Storage
2. Temperature Cycling Test (Temperature Cycling Test)
3. External Short Circuit Test (External Short Circuit Test)
4. Crushing of Cells
5. Cell Protection Against a High Charging Rate (Cell Protection Against a High Charging Rate)
6. Overheating test (Thermal Abuse Test)
If you want to know more about battery KC certification, you can call ZRLK for detailed inquiries. Our ZRLK has professionally handled battery KC certification for many years. If you need to handle or have related questions, you can call our company for related information. Professional engineers will answer online for you. If you provide us with product pictures and specifications, we will give us the corresponding cycle, quotation and specific plan according to your product. Welcome to inquire.